Safety

3.1

Intended use

The pumping stations of
and without sewage above the backwater level in the sense of EN 12050-1. The
the collection and automatic lifting of wastewater without sewage above the backwater level in the sense of EN
12050-2.
National regulations for the use of wastewater with or without sewage can vary in different countries. On account
of the greater operational safety, KESSEL recommends observing the designated use even in countries with
deviating regulations.
Use in a potentially explosive environment is only permissible when the pumping station has the respective
Product description.
Any conversion work
or attachments (incl. use of components not designated for use together such as e. g. pump 400V with control
unit 230V)
use of non-genuine spare parts or accessories
carrying out of pump repair(s) by companies or persons not
authorised by the manufacturer
use under conditions other than those required in the current guidelines and standards
without the express and written approval of the manufacturer can lead to a loss of warranty.
Note:
case of possible voltage peaks. This does not protect against lightning. If such requirements exist, an appropriate
protective device must be installed on site.
3.2
Persons who install the pumping station must
– be at least 18 years old.
– be familiar with and follow the relevant technical rules and safety regulations.
the relevant provisions, current standards and accident prevention regulations, can carry out the required tasks
and both recognise and avoid any possible hazards.
Work on electrical components may only be carried out by appropriately trained skilled personnel and in
compliance with all relevant accident prevention regulations (UVV).