Technical data
- power supply: 230 VAC / 50 Hz
- electronic limit swiches
- obstacle detection
- operating temperature: ~ -10oC ~ +50oC (protection degree IP44)
- maximum time of continous work: 4 min.
- The tubular drive units can be connected in parallel for operation with a
single control switch and without any additional power and control systems.
The manufacturer reserves a margin tolerance with respect to the catalogue
data due to use in a variety of conditions.
ALUPROF S.A.
Electrical connections
Zasilanie 230V /
Brown wire - phase (direction 1)
Black wire - phase (direction 2)
Blue wire - neutral
Yellow / green wire - ground
White wire – limit position setting
" In accordance with the provisions of the Directive of the European Parliament and of the Council 2012/19 / EU of 4 July 2012 on waste
electrical and electronic equipment (WEEE), it is prohibited to place of used equipment together with other wastes, marked with crossed
out wheeled bin symbol. The users are obliged to transfer their used equipment to a designated collection point for proper processing.
The marking means, at the same time, that the equipment was put on the market after 13 August 2005.
These legal obligations have been introduced to reduce the amount of waste generated from waste electrical and electronic equipment
and to ensure an appropriate level of collection, recovery and recycling. The equipment does not contain any dangerous components,
which would have any particularly negative impact on the environment and human health."
PROGRAMING MANUAL FOR DM MOTORS, SERIES BD
PROGRAMING MANUAL FOR DM MOTORS, SERIES BD
Headquarters; Production plant in Bielsko-Biała
Warszawska 153, 43-300 Bielsko-Biała, Poland
+48 33 81 95 300, fax. +48 33 82 28 512
- Installation of the motor should be carried out
by authorized persons
- The motor is designed for use in dry rooms and should
not be exposed to direct weather conditions.
- The motor should be powered by a separate circuit and
protected by a quick fuse for example: circuit breaker
type B10
- The maximum number of motor units connected
in parallel depends on the making capacity of the control
switch and the long-term withstand load of the power
supply line (the maximum is 10 drive units).
- 6 -
Production plant in Opole
ul. Gosławicka 3, 45-446 Opole, Poland
tel. +48 77 40 00 000, fax. +48 77 40 00 006
e-mail: Aluprof@aluprof.eu
NOTE