STRUCTURE
1. Module connection wire connector (IN);
2. Programming switch (SW1);
3. Module connection wire connector (OUT);
4. Operation selection jumper:
in stand-alone mode
in 2Voice and Ipercom systems
5. Terminal board
DESCRIPTION OF TERMINALS
AH
Common reference for time slots and door opener inputs
S4
Common contact relay 2
S5
Normally closed contact relay 2
S6
Normally open contact relay 2
S1
Common contact relay 1
S2
Normally closed contact relay 1
S3
Normally open contact relay 1
A1
Relay 1 hall door release button
A2
Relay 2 hall door release button
H
Time slot input
-~
Power negative (12Vac or 12Vdc)
+~
Power positive (12Vac or 12Vdc)
PROGRAMMING FOR OPERATION IN STAND-ALONE MODE
MASTER PASSWORD PROGRAMMING PROCEDURE
The master password is required to access device confi guration programming mode.
Power the device.
Press the programming switch (SW1) three times in 5 seconds.
The device generates 3 confi rmation beeps and the button
Enter the password code (from 3 to 8 digits).
Press
to confi rm.
The device will beep 3 times to confi rm. The button
normal operation.
To modify the master password, if required, disconnect the device from the power supply for at
least fi ve seconds and repeat the procedure described above.
DS1168-007
1
2
3
turns from blue to red.
turns from red to blue and the device switches to
4
5
9