• When connecting a battery to the charger, always connect the charging
cable to the charger first, then the battery to the charger/charging cable.
When disconnecting, proceed in reverse order (first disconnect the
rechargeable battery from the charging cable, then the charging cable from
the charger).
Failure to do so presents the danger of a short circuit (e.g. from the two
circular connectors on the charging cable).
• Only ever charge one battery or battery pack at a time.
• If you wish to charge battery packs that you have manufactured yourself, the
cells must be identical in their construction (same type, same capacity, same
manufacturer). The cells must also be charged to the same level (LiPo
batteries can be balanced out using the balancer. This is, however, not
possible with other battery packs such as NiMH or NiCd).
General operation of the menus (overview see chapter 10):
• Select the desired submenu from the main menu using the „BATT TYPE/STOP" button
as described and confirm your selection with the button „START/ENTER".
• Using the buttons „INC" and „DEC", the various configuration options are called up.
• To modify a value, push the „START/ENTER" button - the display then flashes.
• Modify the value shown in the display using the „INC" and „DEC" buttons.
• Save the (modified) value with the „START/ENTER" button.
• Exit the configuration menu using the „BATT TYPE/STOP" button. It then returns to the
main menu.
66