SLEEP MODE:
- The mist output level setting can no longer be changed, it is set to 300 ml/h.
- If you had previously shut off warm mist generation, this will restart.
- The timer is programmed automatically to 8 hours.
- The brightness of the display reduces after approx. 1 minute.
TURBO MODE:
- The mist output level setting is programmed to 500 ml/h automatically.
- Warm mist generation can be enabled or disabled. To do so, press the "Hot/Cool" button (item 12, scheme 2).
- The timer and the humidity level can still be programmed in this mode (item 14, scheme 2).
AUTOMATIC MODE:
- The mist output level setting is programmed to 400 ml/h automatically.
- Warm mist generation can be enabled or disabled (item 12, scheme 2).
- The default programmed humidity level is 70%. The humidity level cannot be changed in this mode. The appliance will
shut down once this humidity level has been reached.
- As for the timer, it can be programmed (item 14, scheme 2).
Mist output
Low
level:
120 ml/h
8) When programming the humidity level (item 14, scheme 2)
All you need do is press the programming button once and select the desired mist output rate using the "More" and "Less"
buttons. The chosen rate will continue to flash 5 seconds before returning to the home display screen.
Accordingly you will have the option of selecting a level between 30 and 70% or going beyond 70%, the "CO" function
indicating "continuous".
9) When programming the timer (item 14, scheme 2)
You need to press the programming button twice. The time may be changed using the "More" and "Less" buttons. The chosen
duration will continue to flash 5 seconds before returning to the home display screen.
Programming range for duration: between 0 and 8 hours.
Important notes:
- Use only fresh, distilled or demineralised water in order to prevent any malfunction.
- Do not pour water into the diffusing nozzle in order to prevent any malfunction or fire risk (the part of the appliance from
which mist is discharged).
- Make sure the tank cap is sealed hermetically after filling so as to avoid leakage or potential electric shocks.
- The tank must be kept clean. If there is any dirt around the mist discharge nozzle, clean it with a brush or a damp cloth.
Warning: EVEN THOUGH THERE IS A SAFETY CUT-OUT THAT SWITCHES OFF THE TRANSDUCER, DO NOT LEAVE THE APPLIANCE
SWITCHED ON WHILE YOU ARE NOT USING IT.
Maintenance and storage:
If the water contains too much calcium and too much magnesium, it may deposit a "white powder" in the appliance. If this
sediment is deposited on the transducer (a white ceramic disc the generates ultrasound (i)), this will prevent the "NOTUS"
humidifier from operating correctly.

Maintenance

We recommend:
1) Using fresh, distilled or demineralised water each time the appliance is used.
2) Cleaning the tank every 2 days and cleaning the transducer every week.
Medium
High
210 ml/h
300 ml/h
Automatic
Turbo mode
mode
400 ml/h
500 ml/h