TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
5
300
OPEN WORK. T .
5
300
CLS WORK. T
0
180
TCA
TRF. L GHT.
1
180
CLR. T
1
240
output time
 0
(LEO B
CBB DL2 3
120 F02)
(LEO B
CBB DL2
3 120 F02
PHOT
USA16)
99
OP. D IST. S LOUD
(LEO B
CBB DL2 3
230 L02)
1
(LEO B
CBB
DL2 3 230
SV)
  0
(LEO B
CBB DL2 3
120 F02)
(LEO B
CBB DL2
3 120 F02
PHOT
USA16)
99
CL. D IST. S LOUD
(LEO B
CBB DL2 3
230 L02)
1
(LEO B
CBB
DL2 3 230
SV)
PARTIAL
10
50
OPENING
1
99
OP. F ORCE
1
99
CLS. F ORCE
1
99
OP. S LWD. F ORCE
CLS. S LWD.
1
99
FORCE
0
99
BRAKE
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
26 - LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-LEO B CBB DL2 3 120 F02 PHOT USA16 - LEO B CBB DL2 3 230 SV
INSTALLATION MANUAL
Default
Personal
Opening operation time [s]
300
Closing operation time [s]
300
Automatic closing time [s]
40
Time-to-clear traffic light
40
Activation time of the
10
timed output [s]
0
(LEO B CBB
DL2 3 120
F02)
(LEO B CBB
DL2 3 120
F02 PHOT
Slow-down distance
USA16)
during opening [%]
30
(LEO B CBB
DL2 3 230
L02)
(LEO B CBB
DL2 3 230 SV)
0
(LEO B CBB
DL2 3 120
F02)
(LEO B CBB
DL2 3 120
F02 PHOT
Slow-down distance
USA16)
during closing [%]
30
(LEO B CBB
DL2 3 230
L02)
(LEO B CBB
DL2 3 230 SV)
Partial opening [%]
20
Leaf force during
75
Leaf force during closing
75
Leaf/leaves force during
opening during
75
Leaf/leaves force during
closing during
75
slow-down [%]
0
Programming number of
0
maintenance threshold
Definition
Description
Maximum motor operation time, during opening.
Set the operation time so that it's slightly longer than the complete ope-
rating cycle time. The value is changed by the Autoset cycle, adapting it
to the operation time detected
Maximum motor operation time, during closing.
Set the operation time so that it's slightly longer than the complete ope-
rating cycle time. The value is changed by the Autoset cycle, adapting it
to the operation time detected
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
zone [s]
Activation length of timed radio channel output in seconds
Slow-down distance for motor(s) during opening, given as a percentage of
total travel.
CBB DL2 3 230 SV)
The Autoset cycle changes the slow-down distance values if they don't allow
at least 50cm of travel at slowed speed.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET" , obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of
total travel.
CBB DL2 3 230 SV)
The Autoset cycle changes the slow-down distance values if they don't allow
at least 50cm of travel at slowed speed.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET" , obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation
of PED pedestrian command.
Force exerted by leaf/leaves during opening.
[if encoder = 0 or 1] the set force value represents the network voltage %
that is supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an
opening [%]
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing.
[if encoder = 0 or 1] the set force value represents the network voltage %
that is supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an
[%]
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
"Force exerted by leaf/leaves during opening at slow-down speed. "
[if encoder = 0 or 1] the set force value represents the network voltage % that
is supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
slow-down
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
"Force exerted by leaf/leaves during closing at slow-down speed. "
[if encoder = 0 or 1] the set force value represents the network voltage % that
is supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
Braking [%]
Percentage of braking applied to stop motion of motor(s).
Allows you to set a number of operations after which the need for main-
operations for
tenance will be reported on the AUX output configured as Maintenance
or Flashing Light and Maintenance .
[in hundreds]
(A minimum deceleration space of 75 cm is ensured, only for LEO B
(85cm for LEO B CBB DL2 3 230 SV)
(A minimum deceleration space of 75 cm is ensured, only for LEO B
(85cm for LEO B CBB DL2 3 230 SV)