2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Undo the screws (E) to remove the electrical
equipment box (F).
5 - Undo the screws (G) to remove the lid (H).
6 - Connect the circuit-breaker (A) to the terminal
board (L) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 22 ).
3 - Change the pilot light nozzle (see page 22).
4 - Adjust the minimum settings of the gas control
valves of the burners (see page 20 ).
5 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.
7 - Replace the lid (H), the electrical equipment
box (F) and the control panel (D) on completion
of the operation.
A
- 19 -
IDM-39610801300.tif
IT
GB
DE
FR
ES
IDM-3960200250.tif
English