Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.
Faults
Smell of gas
The pilot light does not ignite
The pilot light goes out.
The flame is yellow
Burner control knob is stiff

FAULT

The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
Causes
Occasional leak because flame has
gone out
The spark ignition devices are not
working
Air in pipelines due to long period out
of use
The thermocouple has not warmed
up enough
Burner dirty, heat exchange pipes
clogged, condensation drips
Gas valve malfunction
- 13 -
Remedies
Turn off the gas supply tap and ven-
tilate the room
Check that the ignition devices are in
good working order Light by hand
with a naked light
Important
Contact the after-sales
Make more attempts to light the
flame
Make more attempts to light the
flame
Important
Contact the after-sales
service.
Important
Contact the after-sales
service.
6