3. Waste water is collected in the waste water tray.
Cleaning, Care & Maintenance
· Switch off and disconnect from the power supply before cleaning.
· Clean the interior of the appliance as often as possible.
· Do not use abrasive cleaning agents. These can leave harmful residues.
· Clean the door seal with water only.
· Always wipe dry after cleaning.
· Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
· Take care when cleaning the rear of the appliance. Sharp edges can cut.
An agent or qualified technician must carry out repairs if required.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance. We recommend that
our agent or qualified technician clean the clean the condenser.
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to
your retailer.
Fault
The appliance
is Plug and lead are damaged
not working
The
appliance Appliance is located near a heat Move the refrigerator to a more suitable
turns on, but the
temperature is too
high/low
The appliance
is
leaking water
15
Probable Cause
The unit is not switch on
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator Defrost the appliance
Condenser blocked with dust
Doors are not shut properly
source or air
condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being Remove any excessive hot foodstuffs or
stored in the appliance
Appliance is overloaded
The appliance is
levelled
The discharge outside is blocked Clear the discharge outlet
Movement of water to the drain Clear the floor of the
is obstructed
The water container is damaged Call your agent or qualified technician
The drip tray is over flowing
Loose nut/screw
Action
Check the unit is plugged in correctly and
switched on
Call your agent or qualified technician
Replace the fuse
Check power supply
Call your agent or qualified technician
Call your agent or qualified technician
Check doors are shut and seals are not
damaged
flow
to the
location
Increase ventilation or move appliance
to a cooler position
blockages to the fan
Reduce the amount of food stored in the
appliance
not properly Adjust the screw feet
appliance(If applicable)
applicable)
Empty the drip tray(if applicable)
Check and tighten all nuts and screws
to level
the
appliance (if

Werbung