be carried out by a Skilled Technician who is also a Qualified Eletrician, i.e. a person with professional training
who is authorised to check, install and repair electrical equipment correctly and according to current regulations
in the country where the water cleaner is installed.
• Total Stop: this stops operation of the water cleaner every time the control lever on the cleaner gun is released.
• Easy Start: this aids starting up the water cleaner by lowering the pressure for the first moments of its operation.
2 f
eatures and

ELECTRICAL CONNECTION

Mains power supply
Absorbed power
Fuse

HYDRAULIC CONNECTION

Maximum inlet water temperature
Minimum inlet water temperature
Minimum inlet water flow
Maximum inlet water pressure
Maximum priming depth
PERFORMANCE
Maximum water flow
Maximum pressure
Maximum water outlet temperature
Recoil of cleaner gun
Sound level
Operator arm vibrations
WEIGHT AND DIMENSION
Lenght x width x height
Weight
Diesel tank capacity
Detergent tank capacity
All features and technical specifications are only indications. The Manufacturer reserves
2.1 I
dentIfICatIon of
Please also refer to figures 1 to 2, which are located at the start of these operating and maintenance instructions.
1. Water inlet connector
2. Main switch
3. Hose reel ring nut
4. Hose reel
5. Hose reel knob
7. High pressure hose
9. Seat for water gun/lance hose
10. Plate "Read the manual before..."
12. Identification plate
13. Plate "Do not spray towards persons,..."
14. Power supply wire
16. Water gun
17. Lance hose
18. Nozzle-holding head
16
t
s
eChnICal
peCIfICatIons
the right to modify the appliance as it deems necessary..
C
omponents
PW 300 HC - IP 3000 HS
700 l/h / 185 US gph
0,8 MPa / 8 bar / 116 psi
540 l/h / 143 US gph
15 MPa / 150 bars / 2176 psi
890 x 500 x 820 mm - 35 x 19,7 x 32,3 in
19. Nozzle cleaning hole
20. Nozzle
21. Lance stand
24. Water gun lever
25. Water gun lever safety stop
26. Handle
27. Water adjusting knob
28. Stack
29. Plate "Caution: Hot surfaces"
30. Pressure gauge
31. Detergent tank plug
32. Gas oil tank plug
33. Water suction filter/gasket
34. Control panel
35. Water suction connector
230 V / 1~50 Hz
2,7 kW
16 A
40 °C / 98 °F
5 °C / 41 °F
0 m / 0 ft
90 °C - 194 °F
21,4 N
82 dB (A)
1,7 m/s
2
87 kg / 191,8 lb
20 l / 5,3 US gal
4,5 l / 1,2 US gal