Operation

Switching on/off and setting the temperature
Switching on and setting the temperature:
Plug the mains plug into an appropriate wall socket and press
the ON/OFF switch
Turn the temperature control
NOTE
Remove the protective cap from the soldering tip
Before using the soldering station for the first time and also before
using a new soldering tip, the soldering tip
NOTE
The prerequisite for perfect soldering is to use appropriate
solder. Furthermore, it is not possible to make perfect soldered
joints unless the correct soldering temperature is used. If the
soldering temperature is too low, the solder is not sufficiently
fluid and causes dirty solder joints (so-called cold solder joints).
If the soldering temperature is too high, the soldering agent can
burn and the solder does not flow. In addition, the materials to
be processed can be destroyed.
Use the temperature settings below for the most common applications.
These may vary depending on the solder/manufacturer.
Level "Min" = room temperature
Level 1 = approx. 100°C – warm-up level and for solders with
correspondingly low melting point
Level 2 = 200°C melting point of the most frequently used soft
solders
PLS 48 C1
to position "I".
to set the desired temperature.
.
must be tinned.