2. Safety instructions
The instrument is built and tested in accordance with
DIN VDE 0411 Part 1/ EN 61010-1
DIN VDE 0411 Part 2-032/EN 61010-2-032
DIN VDE 0411 Part 2-033/EN 61010-2-033
DIN VDE 0411 Part 031/EN 61010-031
DIN VDE 0413 Part 13/EN 61557-13
and has left the factory in perfectly safe technical condition.
To preserve this condition and to ensure safe operation of the device, the user
must observe the notes and warnings given in these instructions at all times.
Improper handling and non-observance of the warnings might involve severe
injuries or danger to life.
WARNING! Be extremely careful when working with bare con-
ductors or main line carrier! Contact with live conductors will
cause an electric shock!
The BENNING CM 9-1 must be used in electrical circuits of over-
voltage category III with a conductor for a maximum of 600 V
to earth or of overvoltage category IV with a conductor for a
maximum of 300 V to earth only.
Only use suitable measuring leads for this. With measurements
within measurement category III or measurement category IV,
the projecting conductive part of a contact tip of the measuring
leads must not be longer than 4 mm.
Prior to carrying out measurements within measurement cat-
egory III and measurement category IV, the push-on caps pro-
vided with the set and marked with CAT III and CAT IV must be
pushed onto the contact tips. The purpose of this measure is
user protection.
Please observe that work on live parts and electrical compo-
nents of all kinds is dangerous! Even low voltages of 30 V AC
and 60 V DC may be dangerous to human life!
Before starting the current clamp multimeter, always check the
device as well as all measuring leads for damages.
If it can be assumed that safe operation is no longer possible, switch the device
off immediately and secure it against unintended operation.
Safe operation can be assumed to be no longer possible, if
-
the device or the measuring leads exhibit visible damages,
-
the device no longer works,
-
the device has been stored under unfavourable conditions for a longer pe-
riod of time,
-
the device was exposed to extraordinary stress during transport, or
-
if the device or the measuring leads are exposed to moisture.
Maintenance:
Do not open the multimeter, because it contains no components
which can be repaired by the user. Repair and service must be
carried out by qualified personnel only!
Cleaning:
Regularly wipe the housing by means of a dry cloth and clean-
ing agent. Do not use any polishing agents or solvents!
3. Scope of delivery
The scope of delivery of the BENNING CM 9-1 comprises:
3.1 One BENNING CM 9-1
3.2 One safety measuring lead, red (L = 1.4 m)
3.3 One safety measuring lead, black (L = 1.4 m)
3.4 One compact protective pouch
3.5 Two 1.5 V micro batteries (IEC LR03/ AAA)
3.6 One operating manual
Parts subject to wear:
-
The BENNING CM 9-1 is supplied by means of two integrated 1.5 V micro
batteries (IEC LR 03/ AAA).
-
The above mentioned safety measuring leads (tested spare part, part no.
10/ 2019
BENNING CM 9-1
11