Connect the transmitter to the
PRINTER connector on the rear panel
of the receiver.
3
Connect the printer port that supplies
USB bus power to the DC IN
connector on the rear panel of the
receiver using the supplied USB cable.
The LINK indicator on the front panel
of the transmitter starts flashing and
the currently specified channel
indicator lights up solid (channel 1 by
factory default).
4
Press the CH button on the rear panel
of the receiver to change channel.
The channel changes and the internal
settings are modified each time you
press the CH button. The LINK
indicator turns off while the internal
settings are modified, and the channel
indicator flashes three times. After the
settings are modified, the changed
channel indicator is lit solid and the
LINK indicator starts flashing.
Note
Do not disconnect the USB bus power
while the LINK indicator is off. The
system may no longer operate if the
settings information is corrupted.
5
Disconnect the USB bus power and the
transmitter from the receiver, in that
order.
The transmitter can be disconnected
even while the channel indicator is lit.
Follow the procedure in the "Connecting"
section to connect the printer and medical
device.
Notes
• If the channels of the transmitter and
receiver are different, reconfigure the
16
Connecting
GB
channel settings using the procedure in
the "Using Multiple Wireless Print
Systems" section.
• This system automatically connects a
receiver and transmitter set to the same
channel. If there are multiple transmitters
and receivers set to the same channel
within the same communications area, an
unintended combination of devices may
be connected, causing printing by an
unintended printer. When using multiple
devices simultaneously, always set the
devices to different channels.