en
Observe ambient
temperature and
ventilation
The climatic class can be found on the
rating plate and indicates the ambient
temperatures at which the appliance can
be operated.
Climatic class
SN
N
ST
T
Ventilation
Fig. 4
The air on the rear panel of the appliance
heats up. The warm air must be able to
escape. Otherwise, the refrigerator must
work harder. This will increase the power
consumption.
Therefore: Never cover or block ventilation
openings!
22
Permitted ambient
temperature
+10 C to 32 C
+16 C to 32 C
+18 C to 38 C
+18 C to 43 C
Connecting the
appliance
After installing the appliance, wait at least.
½ hour before switching on the appliance.
During transportation the oil in the
compressor may have flowed into the
refrigeration system.
Before switching on the appliance for the
first time, clean the interior (see Cleaning).
The socket should be freely accessible.
Connect the appliance to 220 240 V/
50 Hz alternating current via a correctly
installed earthed socket. The socket must
be fused with a 10 A fuse or higher.
If the appliance is to be operated in
a non European country, check on the
rating plate whether the indicated
voltage and current type correspond
to the values of your mains supply.
The rating plate is situated in the
bottom left hand side of the appliance.
The power cord may be replaced by
an electrician only.