6.4.2 Fixing to parapet or ceiling mount
Fix the adaptor (01) to the bottom of the unit using
the 4 flat countersunk screws (02) with hexagonal
socket M10x20mm in stainless steel (A4 class 70)
supplied.
Make sure the thread are free of dirt and debris.
Apply a generous amount of thread locking
compound (Loctite 270) into the threaded holes in
the base of the device.
Pay attention to the fixing. Tightening
torque: 35Nm.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
01
Fig. 6
Use the external holes in the adapter to fix the
assembled unit to the parapet or to the ceiling. Use
screws that can bear at least 4 times the weight of
the unit.
Fig. 7
18
02
Ø 238
6.4.3 Bracket mounting
The bracket can be fixed to the vertical wall. Use
screws and wall fixing devices that can bear at least
four times the weight of the unit.
Then, fix the device to the bracket using the 4 flat
washers, the 4 spring washers in stainless steel and
the 4 hexagonal head screws in stainless steel (A4
class 70) supplied (M10x20mm).
Fig. 8
Make sure the thread are free of dirt and debris.
Apply a generous amount of thread locking
compound (Loctite 270) on the 4 screws.
Tighten the screws.
Pay attention to the fixing. Tightening
torque: 35Nm.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
MNVCMPXHDC_1916_EN