Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Fronius Acctiva Easy 1202 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Acctiva Easy 1202:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Troubleshooting

General errors
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Errors in test
Before the open circuit voltage test, nothing appears on the display
mode
After the battery connection has been established, not all display elements are activated
Cause:
Remedy:
Cause:
Remedy:
Skip the startability display
After the open circuit voltage test, the charger switches immediately to the alternator test
Cause:
Remedy:
Errors during
Charger switches off during charging
charging
Cause:
Remedy:
These symbols are displayed alternately
Charger leads connected to wrong poles
Connect battery poles correctly
These symbols are displayed alternately
Battery open circuit/contact fault
Check charger leads, contacts and battery poles
These symbols are displayed alternately
Charger lead short circuit
Check charger leads, contacts and battery poles for short circuit
Battery is flat or in deep discharge
Recharge the deep-discharge battery
Charger leads connected to wrong poles
Connect battery poles correctly
Very good battery, optimal startability
System in very good condition. No remedial action necessary.
High ambient temperature. Charger overheating.
Allow device to cool down. Charging will recommence automatically once the
charger has cooled sufficiently
35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis