PIPING CONNECTION (FIGURE 26)
for the left (Wc) and right (Wf) piping, remove the respective pipe covering (Wb or Wg) from the lateral panel.
It is recommended to keep the pipe covering that has been removed, since it can be re-used if the
air conditioner is installed in another position.
For the rear right (We) and rear left (Wd) piping, install the pipes as illustrated in figure 26.
Bend the connection pipe, which must be laid at a max. distance of 43 mm from the outside wall.
fix the end of the connection pipe (Wi). (see "execution, installation and connection of the refrigeration lines").
Key (figure 26)
Wa Pipe-holder
Wb Pipe protection (left)
Wc left piping
Wd left rear piping
We right rear piping
Wf
right piping
a. Attach the upper bracket present in the rear part of the indoor unit to the upper hook of the fixing bracket
(L1) (figure 24).
b. Move the unit laterally to ensure it is correctly attached to the fixing hook (L1).
c. Piping connection is easily performed by lifting the indoor unit and introducing cladding between the same
and the wall.
remove the cladding once connection has been completed.
d. Push the lower part of the indoor unit towards the wall to attach it to the fixing bracket (L1) (figure 24).
e. try and move the indoor unit laterally and vertically to make sure that it is attached securely.
2.4.3 -
DRAIN PIPE CONNECTION (FIGURE 27)
a. insert the drain pipe (Wa), making sure that it slopes downwards.
b. if necessary, connect an extension (Wc) to the drain pipe, isolate the joint with a protection pipe (Wc).
2.4.4 -
ELECTRIC CONNECTIONSI (FIGURE 35)
a. remove the panel (21)
b. Unscrew the screw and remove the protection (22).
c. Connect the cables to the terminal board (23) as illustrated in figure 46.
d. Wrap the cables not connected to the terminals in electrician's tape, in a way that they cannot
touch any electric component.
e. Block the cable using the cable tie.
EN - 18
Wg Pipe protection (right)
Wg indoor unit outlet
Wi
Connection pipe
Wl
Upper hook
Wm lower hook
Wn Cladding material