Herunterladen Inhalt Inhalt Diese Seite drucken

Klarstein Townhouse Bedienungsanleitung Seite 28

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
28
Air drying function
After using the cooling and humidifying function, the high-speed fan should be used to
dry the honeycomb air filters.
Pressing and holding the speed button for 3 seconds activates the air drying function.
Once the air drying function is activated, the current wind speed is set to the next higher
level and then directly to high speed for 20 minutes. The level before the automatic
change to maximum speed is not displayed. Once the air drying function has been
activated, the maximum speed display should turn on and off at 0.5 second intervals
until the unit automatically turns off after 20 minutes.
As long as the air drying function is activated, all other functions are deactivated. During
the air drying mode, only the On/Off button works. All other function keys are disabled
in this mode. If the unit is turned off while starting the air drying function, the previous
operating status will be restored when the unit is turned on again and the status of the air
drying function will not be displayed.
If the unit has been turned off directly after the Cooling And Humidification mode
without previously activating the air drying function, it is necessary to restart the unit and
activate the air drying function to dry the honeycomb filters.
Mode reminder when switched on again
• If the power plug is unplugged while the unit is on and the power plug is plugged
back into the outlet, the unit will beep 10 times (once per second) with no screen
indication. After 30 seconds, the previous operating status is restored.
Note: The previous function will be restored unless the unit was in „soft wind" mode
because there is no reminder function for it.
• When the On/Off button is pressed, the unit should automatically return to the
previous operating status after 30 seconds.
• The countdown of the timer function should also be saved and an error rate of
maximum 5 minutes is possible each time the unit is switched off (the timer does not
take into account the time when the unit is switched off).
• If the unit was switched off when the power plug was unplugged, the unit will also
be switched off when the power plug is plugged in again.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis