Herunterladen Inhalt Inhalt Diese Seite drucken

AEG AIK1344R Benutzerinformation Seite 64

Vorschau ausblenden Andere Handbücher für AIK1344R:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

64
www.aeg.com
Problem
The compressor does not
start immediately after
pressing the "FROSTMAT-
IC", or after changing the
temperature.
Water flows on the rear plate
of the refrigerator.
Water flows into the refriger-
ator.
Water flows on the floor.
Temperature cannot be set.
The temperature in the ap-
pliance is too low/too high.
There is too much con-
densed water on the rear
wall of the refrigerator.
Possible cause
This is normal, no error has
occurred.
During the automatic de-
frosting process, frost melts
on the rear plate.
The water outlet is clogged.
Food products prevent that
water flows into the water
collector.
The melting water outlet is
not connected to the evapo-
rative tray above the com-
pressor.
The "FROSTMATIC func-
tion" is switched on.
The temperature regulator is
not set correctly.
The door is not closed cor-
rectly.
The food products' tempera-
ture is too high.
Many food products are
stored at the same time.
The thickness of the frost is
greater than 4-5 mm.
The door has been opened
often.
The FROSTMATIC function
is switched on.
Door was opened too fre-
quently.
Solution
The compressor starts after a
period of time.
This is correct.
Clean the water outlet.
Make sure that food prod-
ucts do not touch the rear
plate.
Attach the melting water
outlet to the evaporative
tray.
Switch off "FROSTMATIC
function" manually, or wait
until the function resets au-
tomatically to set the tem-
perature. Refer to "FROST-
MATIC function".
Set a higher/lower tempera-
ture.
Refer to "Closing the door".
Let the food products tem-
perature decrease to room
temperature before storage.
Store less food products at
the same time.
Defrost the appliance.
Open the door only if neces-
sary.
Refer to "FROSTMATIC
function".
Open the door only when
necessary.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis