CAM1000
• When working on the following cables, only use insulated cable lugs, plugs and tab
sleeves:
– 30 (direct input from positive battery terminal)
– 15 (connected positive terminal, behind the battery)
– 31 (return cable from the battery, ground)
– 58 (reversing light)
Do not use porcelain wire connectors.
• Use a crimping tool to connect the cables.
• Screw the cable when connecting cable 31 (earth)
– Screw on the cable using a cable lug and gear disc to one of the vehicle's earth
bolts or
– Screw the cable to the sheet metal body work using a cable lug and a self-tapping
screw.
Make sure there is a good earth connection.
• If you disconnect the battery, all data stored in all volatile memory will be lost. Data
may have to be reset. Please follow the instructions of the respective vehicle manu-
facturer in this case. You can find instructions for making these settings in the operat-
ing manual.
• You can find instructions for making these settings in the operating manual.
• To prevent damage when drilling, make sure there is sufficient space on the other
side for the drill head to emerge.
• Deburr all drill holes and treat them with a rust-protection agent.
Observe the following instructions when working with electrical parts:
A
NOTICE!
• When testing the voltage in electrical cables, only use a diode test lamp or a
voltmeter.
Test lamps with a bulb consume too much voltage, which can damage the vehicle's
electronic system.
• When making electrical connections, ensure that:
– They are not kinked or twisted
– They do not rub on edges
– They are not laid in sharp-edged through-holes without protection.
• Insulate all connections.
• Secure the cables against mechanical stress with cable binders or insulating tape, for
example to existing lines.
• Follow the installation and operating manual for the monitor.
EN
Safety and installation instructions
5