11 Disassembly
11 Disassembly
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Close off the gas supply.
• Switch off the entire welding system.
• Disconnect all electrical connections.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
• Note the following instructions:
8 Putting out of operation on page EN-16
1 Disconnect the cable assembly from the wire feeder.
2 Remove the parts to be disconnected (change body, bracket, CAT robot mount, torch neck).
EN - 20
®
ABIROB
BAL.0125 • 2019-04-15
A