Description

Product overview

6
5
4
3
2
1
12
11
1
Connector
2
Control valve
3
Inner mask
4
Visor
5
Visor frame
6
Upper head-harness
connector
12
7
8
9
10
7
Harness
8
Face seal
9
Carrying strap
10 Mask body
11 Clamping ring
12 Exhalation valve cover
(approved by Dekra Exam)

Feature description

The full face masks have a round-thread connector according to
EN 148-1. This makes the full face masks suitable for respiratory filters,
self-contained breathing apparatuses and/or airline equipment. The full
face masks can be used in a temperature range of -30 °C +60 °C.
Mask spectacles can be inserted for users who wear spectacles. A
protective welding visor can also be fitted.

Intended use

The full face masks protect the face and eyes against aggressive
media.

Limitations on use

WARNING
!
Beards and sideburns in the sealing area of the full face mask
will cause leakages! Therefore the full face mask should not
be used by anyone with facial hair of this sort. Earpieces in
the sealing area also cause leakages. Use special mask
spectacles.