Installation
» Cleanly break out the knock-outs in the appli-
ance cover. Deburr any sharp edges with a file if
necessary.
» Slide the lower back panel under the connection
pipes of the tap and click the lower back panel into
place.
» Secure the connection pipes to the appliance.
10.2.6 Operation with preheated water
You can restrict the maximum inlet temperature by install-
ing a central thermostatic valve.
10.2.7 Temperature limit
1 Position "Tred" (55 °C): Temperature limit
2 Position "Tmax": No temperature limit, for tempera-
ture setting range, see chapter "Specification / Data
table".
» Remove the appliance cover.
» Slide the switch to the required position.
» Fit the appliance cover.
CAUTION Burns
When operating with preheated water, the set tem-
perature limit may be ineffective.
» In this case, restrict the temperature at the up-
stream central thermostatic valve; see chapter
"Installation / Appliance description / Accesso-
ries".

10.3 Completing the installation

» Open the shut-off valve in the twin connector or the
cold water inlet line.

11. Commissioning

WARNING Electrocution
Commissioning must only be carried out by a qual-
ified contractor in accordance with safety regula-
tions.
26

11.1 Initial start-up

2
1
» Open and close all connected draw-off valves sever-
» Carry out a tightness check.
» Enable the safety pressure limiter by firmly pressing
» Plug the temperature selector cable plug into the
» Fit the appliance cover, ensuring it clicks into place.
» Switch the power supply ON.
» Check the appliance function.
Appliance handover
» Explain the appliance function to users and familiar-
» Make the user aware of potential dangers, especially
» Hand over these instructions.
11.2 Recommissioning
Vent the appliance and the cold water inlet line (see chap-
ter "Settings").
See chapter "Initial start-up".

12. Appliance shutdown

» Isolate all poles of the appliance from the power
» Drain the appliance (see chapter "Maintenance").
al times, until all air has been purged from the pipe-
work and the appliance.
the reset button (the appliance is delivered with the
safety pressure limiter disabled).
PCB.
Check that the appliance cover is seated correctly.
ise them with how it works.
the risk of scalding.
supply.

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ddle lcd 21Ddle lcd 24Ddle lcd 27

Inhaltsverzeichnis