Herunterladen Diese Seite drucken

Operation; Connection And Control Devices; Function Explanation - ESAB ESABMig 325 Betriebsanweisung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
GB
6

OPERATION

General safety regulations for the handling of the equipment can be found on
page 40. Read through before you start using the equipment!
WARNING – TIPPING RISK!
There is a risk of tipping while transportation and operation, if the welding machine leans
o
more than 10
. In that case appropriate securing has to be provided !
6.1

Connection and control devices

1
Mains supply switch
2
Switch, precise control
3
Switch, coarse control
4
Indicating lamp, power supply ON
5
Orange indicating lamp, overheating
6
Space for digital meters (optional), see
page 141
6.2

Function explanation

6.2.1
Overheating protection
A thermal overload cutout protects against overheating. The cutout resets automatically
when the unit has cooled.
6.2.2
Inductance connection
Higher inductance produces a more flowing weld and fewer spatters. Lower inductance
produces a harsher sound and a stable, concentrated arc.
325e
7
Connection for return cable (–), high induc-
tance
8
Connection for return cable (–), low induc-
tance
9
Connection for welding current cable (+)
10
Connection for control cable for wire feeder
11
MCB
– 46 –