Herunterladen Diese Seite drucken

Safety Prescriptions; Building In - ETNA T301ZT Anleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3 phase connection
3 positive without negative 3 a.c. 230 V
Remove the connection between the grey and
the black wire.
The fuse box in your home must be fitted with
a 16 A fuse.
blue
grey
brown
black
yellow/green
L3
L2
L1
230V
230V
230V
positive connection L1 (grey)
positive connection L2 (black)
positive connection L3 (blue and brown)

Safety prescriptions

For the appliance to work well, it is important:
That there is sufficient ventilation to allow
the hob to cool down, in accordance with
the possibilities specified in this chapter.
The ventilation air drawn in by the hob
must not be warmer than 65 °C. Bear this in
mind if the oven is to be built in under the
hob.
That the connecting cable hangs freely and
is not caught by a drawer.
The worktop is flat.

Building in

Cut opening in worktop
Saw the opening in the worktop. This should
be done very accurately (see table).
Also saw out any partitions that may be
present.
The distance from the saw line to the rear wall
and/or side wall is indicated in the table.
Table:
Type of hob
T301ZT
Appliance width x depth
580 x 510 mm
Installation height from top of worktop
51 / 64 mm
Cut out dimensions width x depth
560 x 490 mm
Distance from saw line to rear wall
50 mm minimum
Distance from appliance to side wall
40 mm minimum
Space to be left free around the appliance:
cooker hood
min. 600 mm
cabinet
min. 900 mm (A380ZT)
min. 650 mm
min. 450 mm
min. 40 mm
hob
580/770
510
64
51
560/750
490
min.50
64
A397ZT
A380ZT
580 x 510 mm
770 x 510 mm
51 / 64 mm
51 / 64 mm
560 x 490 mm
750 x 490 mm
50 mm minimum
50 mm minimum
40 mm minimum
40 mm minimum
min. 40 mm
side wall
51

Werbung

loading

Diese Anleitung auch für:

A397ztA380zt