Herunterladen Inhalt Inhalt Diese Seite drucken

Gallagher MBS1800i Betriebsanleitung Seite 13

Vorschau ausblenden Andere Handbücher für MBS1800i:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 68
Gallagher 3E4347 MBS1800i MBS2800i Energizer User Manual
Reference Earth
An addi onal earth stake is required to measure the earth system performance.
a)
Install a single galvanised stake (G878 / G879) at least 60cm (2 ) long, at least
10m (33 ) from the main energizer earth system and at least 10m (33 ) from
any mains cabling, telephone cabling, water pipes or building earth.
b)
Using Underground Cable (G627) connect the reference earth stake to the
black ( ) terminal on the energizer.
Step 3. Connect the fence
WARNING: do not turn energizer on un l a er installa on is complete.
a)
Connect the energizer's red output ( ) terminal to the fence using
Underground Cable (G627). Remove 5cm (2") of plas c coa ng from one end
of the cable. Unscrew the red (FENCE) terminal and insert the wire through the
terminal slot. Screw the terminal closed, ensuring the wire is fi rmly clamped.
b)
A ach the other end of the cable to the fence using a Joint Clamp (G603).
For instruc ons on fence installa on see the Gallagher Electric Fence Guide or go to
www.gallagher.com.
GREEN
To Earth System
BLACK
To Reference Earth
RED
To Fence
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mbs2800i

Inhaltsverzeichnis