[1] Machine and Bin Exterior
Wipe the exterior at least once per week with a
clean, soft cloth. Use a damp cloth containing a
neutral cleaner to wipe off grease or dirt.
[2] Scoop Cleaning/Sanitisation (Daily)
1) Either mix 1 litre of water with 4 ml of 5.25%
sodium hypochlorite solution in a suitable
cont ainer, or t he r e co mme nd ed H os hi z ak i
sanitiser as directed.
2) Soak the scoop in the solution for more than 3
minutes. Rinse thoroughly, and shake to remove
surplus liquid.
Note: Using a cloth to dry may re-contaminate.
[3] Storage Bin Interior Cleaning/Sanitisation
(Weekly)
1) Open the storage bin door, and remove all ice.
2) Remove the thumbscrews securing the baffle.
3) Remove the baffle from the bin.
4) Wash the bin liner and baffle with a neutral non-
abrasive cleaner. Rinse thoroughly.
5) Either mix 5 litres of water with 18 ml of 5.25%
sodium hypochlorite solution in a suitable
cont ainer, or t he r e co mme nd ed H os hi z ak i
sanitiser as directed.
6) Soak a clean sponge or cloth with the solution and
wipe the bin liner surfaces and baffle.
7) Refit the baffle and thumbscrews. Wipe the
surface of the bin door and thumbscrews with the
solution. Close the bin door.
8) The remaining solution can be used to sanitise
utensils.
Note: Do not wipe dry or rinse after sanitising, but
allow to air dry.
[4] Storage Bin Door
Clean the storage bin door at least once a week,
using a neutral non-abrasive cleaner. Rinse
thoroughly after cleaning and sanitise as required.
[5] Air Filter
Plastic mesh air filters remove dirt or dust from the
air, and keep the condenser from getting clogged. If
the filters get clogged, the icemaker's performance
will be reduced. Remove and clean the air filters at
least twice per month:
1) Slide the air filter off the louver.
2) Clean the air filter by using a vacuum cleaner.
When severely clogged, use warm water and a
neutral cleaner to wash the air filter.
3) Rinse and dry the air filter thoroughly, and place it
in position.
Air Filter

2. INSPECTION AND MAINTENANCE

IMPORTANT
To achieve optimum icemaker performance, the
following parts need periodic inspection and
maintenance:
Extruding head (upper bearing)
Housing (lower bearing)
Mechanical seal
These parts should be inspected after two
years from installation or 10,000 hours of
operation, whichever comes first, and once
a year thereafter. Replacement of these
parts is required if wear exceeds factory
recommendations.
Their service life, however, depends on water
qual ity and envi ronment. More frequent
inspection and maintenance are recommended
in bad or severe water conditions.
Consult with your local Hoshizaki service agent
about inspection and maintenance service.
4
Louver
Fig. 2