Herunterladen Inhalt Inhalt Diese Seite drucken

bürkert 2821 Bedienungsanleitung Seite 5

Vorschau ausblenden Andere Handbücher für 2821:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mechanical Data
Dimensions
Housing material
Seal material
Installation position
Pneumatic Data
Modes of operation
A
A
P
Pressure range
Line connections
12
GB
Electrical Data - Controller Type 1094
Operating voltage
Voltage tolerance
Residual ripple
Power consumption
Input signals
Input impedance
Output signal
Ramp time
Monitor signal
Electrical Data - Controller Type 8605
Operating voltage
Voltage tolerance
Residual ripple
Power consumption
Input signals
Input impedance
14
GB
type-dependent, see data sheet
brass, stainless steel
FKM, others on request
any, preferably with the actuator
upwards
Direct acting 3/2-way continu-
ous valve, closed by spring force
when currentless
see rating plate
see rating plate
24 V DC
±10%
±10%
0.5 W (not including valve)
0 to 20 mA, 4 to 20 mA,
0 to 10 V
210 Ω (for current input)
17 kΩ (for voltage input)
PWM (Pulse Width Modulation)
for valve actuation
0 to 10 s, adjustable
1 mV = 1 mA effective
coil current (for setting the
working range)
12 to 24 V DC
±10%
<5%
1 W (not including valve)
0 to 20 mA, 4 to 20 mA,
0 to 10 V, 0 to 5 V
<200 Ω (for current input)
>20 kΩ (for voltage input)
Rating Plate
Example:
Mode of operation
Nominal diameter
Type
Line connection
2832 A 2,0 FKM MS
G1/4
PNVAK - 8bar
24V
DC
0 0 1 0 8 4
Voltage (±10 %)
Order No.
Electrical Data - Valve
Operating voltage
see rating plate
Power consumption
see rating plate
Standard operating
continuous operation, duty cycle
mode
100% acc. to DIN EN 60034-1
Electrical connection
stranded wires, connector lugs
(depending on type and
acc. to DIN EN 175301-803
design)
Form A, Form B
ASSEMBLY
Safety Instructions
WARNING!
Danger of injury during assembly of the valve.
Such work may only be performed by authorized service
personnel and using suitable tools!
After an interruption of the electricity or compressed air
supply, ensure that the process is restarted in a defi ned
or controlled manner!
Fluid Installations
DANGER!
Danger from high pressure!
Working on the unit involves acute risk of injury.
Cut off pressure before detaching lines and valves.
Before assembly
Any installation position, preferably with the actuator up-
wards.
Before assembly, remove contamination from pipes and
fl ange connections.
Seal material
Housing material
8W
Pressure range
W11LA
Power
GB
GB
13
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

282228242832283328342835 ... Alle anzeigen