Herunterladen Inhalt Inhalt Diese Seite drucken

Display / Failures; Temperature Settings; High Cleaning Temperatures; Settings With Control Stick - Dibo JMB-M Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für JMB-M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DISPLAY / FAILURES

Below on the display you can read the actual working hours of the machine
and you can check if the antifreeze filling function is active. Centrally you can
read the working pressure and the output temperature. left on top the engine
speed setting will be displayed (100% is similar to the max. adjusted pressure, in
example below: 250 Bar. When the engine speed setting is 50%, the working
pressure will visualize 125 bar).
For info: configuration of your cleaner must have option steam + option
automatic engine speed setting ! Right on top the setting temperature will be
displayed. Setting: 0°C= burner off & 1°C or more= stand- by temperature.
It can be that the actual temperature has a higher value than
the setting temperature, the burner will not work until the
actual temperature is lower than the setting temperature.

Temperature settings

1
Determine experimentally which engine speed (spray pressure) and at which
temperature the object best can be cleaned without damaging it.
protein-containing material, rubber or synthetic material: knob not higher than
50°C. For the other settings the most diverge materials and/or machines will be
cleaned. Therefore, there are no fixed settings to be displayed.

High cleaning temperatures

2
a cleaning temperature of more than 95°C can only be obtained by reducing
the number l/min produced by the high pressure pump. By placing the throttle
lever to the left ( min. pressure, min flow) or by reducing the engine speed
setting on the display one reduces the number of l/min. The temperature shall
increase maximum until the set value is reached. If the flow is low, the flow
switch shall put the burner out of use, to prevent that the temperature will
increase.
on the left & right side you can check the tank levels (fuel & water).
When the level will decrease below 20%, the display will visualize the level in
red color. above 20%, the filling level will be displayed in green color.
Right below there's an indication if the burner is active or not (through
indication of flame/ strikethrough flame). If you move the control stick 1x up & 1x
down, the burner will turn off. Temperature indication then becomes 0 ° C.
The burner hours are visible on the home screen if pushed on the clock key
(see photo at the bottom right). These burner hours will only be visible at the
time of pushing the (clock) key. .

Settings with control stick

3
The screen includes a number of possible operating pages as shown on this
page (depending the selected options) when the control stick is operated.
General: when not operating the control stick, the control unit will automatically
return for 20 seconds to the main screen.

Control Screen 1 (Operating Instructions)

4
In this screen you can choose to check the various operating instructions.
Move the control stick to the left (no) or right (yes) to select.
DiBO 25
E N
aC T I VaT I o n    

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis