Problem
Heavy build-up of frost, pos-
sibly also on the door.
Interior light does not work
Unusual noises
The compressor does not
start immediately after
changing the temperature
setting.
Water on the floor or storage
shelves.
If the malfunction shows again, contact the
Service Center.
Below data are necessary to help you quickly
and correctly. Write the necessary data here,
refer to the rating plate.
Model description...........................................
(Mod.)
Produkt number..............................................
(PNC)
Serial number.................................................
(S.N.)
Replacing the lamp
Caution! Before replacing the lamp,
disconnect the appliance from mains
power supply. Lamp specification: 220-
240V, max. 1,5W Follow below process
to replace the lamp:
1. Set the temperature regulation knob at
number "O" to switch off the appliance.
www.zanussi.com
ZANUSSI_ZRB24100WA-ZRB24100XA_CS-HU.indd 33
Possible cause
Door seal is not air-tight (pos-
sibly after reversing the door).
Light bulb is defective.
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g. a pipe, on
the rear of the appliance is
touching another part of the
appliance or the wall.
This is normal, no error has
occurred.
Water drain hose is blocked.
2. Unplug the appliance to make sure the ap-
pliance is disconnected from main power
supply.
3. Remove the screw of the lamp cover.
4. Pull the lamp cover out.
5. According to the direction showed in
below picture,unscrew the lamp.
6. Fit new lamp according to the opposite
direction, then replace the lamp cover and
screw.
7. Plug in the appliance and regulate the
knob to the right position.
Bulb cover
Solution
Carefully warm the leaking sec-
tions of the door seal with a hair
dryer (on a cool setting). At the
same time shape the warmed
door seal by hand such that it sits
correctly.
Please look in the replacing lamp
section.
Re-adjust the feet.
Move the appliance slightly.
It necessary, caretully move the
component out of the way.
The compressor will start after a
period of time.
See the clean and care section.
Bulb
Screw
Control Box
33