Herunterladen Inhalt Inhalt Diese Seite drucken

ims PRO POWERDUCTION 110LG Bedienungsanleitung Seite 29

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
Translation of the original instructions
1. Press the button (10), the pump stops and the LED (9) switches on.
2. Place the lance on its supports and put the cable on the ground (to prevent loss of cooling
liquid).
3. Unscrew the accessory by hand.
4. Change and screw the new inductor back on.
5. Press the button again (10).
The pump activates. For 5 seconds, the LEDs display a wait pattern.
If the flow is correct, the machine emits a double «BEEP» and the product is ready to operate.
Otherwise a fault is displayed (refer to the fault code table).
«PURGE» MODE
This mode is only available if the heat is not activated (green switch is off).
1. Push the button (10), the pump stops and the LED (9) lights up.
2. Position the torch on its support and place the cable on the floor (to avoid liquid spillage).
3. Unscrew the accessory by hand.
4. Push and hold the heat authorisation button (2) for 3 seconds until it lights up.
5. Place the torch button above a bucket with a capacity of 10 l minimum.
6. Push the torch button (11). The pump activates until the debit falls under 2 l/minute or for 2 minutes. The machine
displays the debit in decilitre per minute. To interrupt the pump during the cycle, push any button.
7. To empty the cooling circuit, use a blower to blow air (30PSI) at the end of the torch until you can hear the air
flowing or projections of liquid coming out of the tank.
8. To remove the remaining liquid from the bottom of the tank
110 LG: use a vacuum pump or tilt the product to the front.
160LG: unscrew the cap under the Powerduction with a wrench (6 pan of 8).
Once the tank is completely empty, screw the cap back on.
110 LG
9. To top up the cooling liquid, refer to the installation instructions (p9/10).
It is recommended to change the cooling liquid every year, otherwise you may damage the POWERDUCTION's lance.
COOLING CIRCUIT AND «FORCED COOLING» MODE
The Powerduction is equipped with fans. The first, common to 110LG and 160LG, starts when the coolant temperature
reaches 35°C (95°F). The second, only available on the 160LG, starts when the temperature reaches 40°C (104°F). As
soon as the liquid temperature drops below the setpoint values (35°C or 40°C), the fans switch off.
During long periods of use, the POWERDUCTION has a forced cooling mode. To activate it :
1. Set the main switch (1) to ON.
The machine initialises in 2 seconds.
2. Press the activation button (2). The indicator on button (2) and the lance support LED (12) both switch on, indicating
that the machine is ready to operate.
3. Hold (>3 seconds) the button (10). The « Forced cooling» mode is activated.
The cooling fan then starts automatically. The cooling fan will be audible and the «Fan ON» message will appear on the
display.
To stop the «Forced cooling», press the activation button to stop the heating or hold the button (10) again. The message
«Fan OFF» is displayed.
POWERDUCTION 110LG / 160LG
160LG
EN
4
2
29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Powerduction 160lg

Inhaltsverzeichnis