Herunterladen Inhalt Inhalt Diese Seite drucken

Elektroanlage - RAVAGLIOLI KPS305 C2 Originalanleitung

2 säulen hebebühne
Inhaltsverzeichnis

Werbung

11.
IMPIANTO ELETTRICO
Installazione da eseguire dall'utilizzatore
11. ELECTRICAL INSTALLATION
This installation is to be carried out by the user

11. ELEKTROANLAGE

Netzanschluss nur durch Elektrofachkräfte
1
0
NERO 2.5mmq
1
0
2
MORSETTO
TR
TRASFORMATORE COMANDI 30 VA 0-230-400/0-24
TM
CONTATTORE COMANDO MOTORE
STM1
SONDA TERMICA MOTORE
M1
MOTORE
IG
INVERTITORE GEN. DI FASE CON COMANDO SAL./DISC.
FUSIBILE PROTEZIONE SECONDARIO TR.5X20F 2A
FU3
250V (RAPIDO)
FUSIBILE PROTEZIONE PRIMARIO TR: VERS.230V 5X20F
FU2
1A 250V (RAPIDO); VERS.400V 10.3X38 1A 500V GL
(RAPIDO)
TERNA FUSIBILI PROTEZIONE LINEA MOTORI:
FU1
VERS. 230V 10.3X38 25A 500V AM;
VERS. 400V 10.3X38 16A 500V AM
FC1
FINECORSA ROTTURA CATENA
FCS
FINECORSA DI SALITA
FCD
FINECORSA DI DISCESA
RIFER.
NOMENCLATURA
54
KPS305C2 - KPS305C3
KPS306C2 - KPS306C3 - KPS306C3K
HZ
50
FU
60
FU
L1
L2
L3
PE
L1
L2
13
15
9
11
5
IG
16
10
14
12
6
24
23
23
24
25
FU1
17
18
19
19
18
17
18
19
KM
W
U
V
M1
3
11. INSTALLATION ÈLECTRIQUE
L'installation doit être effectée par l'usager
11. ESQUEMA ELECTRICO
La instalación tiene que efectuarse por el utilizador
KPS356LC3K
V
230
400
25A aM
16A aM
25A aM
16A aM
L3
25
9
NERO 1.5mmq
400
24
230
8
0
0
FU2
TR
GIALLO/VERDE 1mmq
TERMINAL
COMMAND TRANSFORMER 30 VA 0-230-400/0-24
MOTOR CONTROL CONTACTOR
MOTOR HEAT PROBE
MOTOR
GEN. PHASE INVERTER WITH RISE/DESCENT COMMAND
SECONDARY PROTECTION FUSE TR 5X20F 2A 250V
RAPID
PRIMARY PROTECTION FUSE TR 5X20F 1A 250V RAPID
(230V VERSION) 10.3X38 1A 500V GL RAPID (VERSION
400V)
TRI PLET OF MOTOR LINE FUSES:
10.3X38 25A 500V AM (VERSION 230V);
10.3X38 16A 500V AM (VERSION 400V)
CHAIN BREAKAGE LIMIT SWITCH
RISE LIMIT SWITCH
DESCENT LIMIT SWITCH
DENOMINATIONS
0472-M001-6
ROSSO 1mmq
10
10
FC1
FU3
2
STM1
3
FCS
FCD
4
5
ROSSO 1mmq
7
3
1
4
2
IG
6
ROSSO 1mmq
KM
7
11
ROSSO 1mmq

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis