Paragraph 8 – Timed Dosage (Frequency signal input "TRIGGER" activated)
Programming
+
PROG
Config.
Config.
Funct.
Funct.
Timer
Q.ty
100
ml
Delay
00.00.00
Interval
00.00.00
Trig.Mode
Low
PausMode
TrigMode
Function mode
Timer
•
Alarms and statuses
Lev = Level Alarm
•
Flw = Flow Alarm
•
•
EM00136320
TrigMode
Low
TrigMode
High
TrigMode
Disabled
Display during operation
empty = pump in stating
•
Stop = pump in stop
•
Paus = pump in pause
•
•
After receiving the set Trigger signal, the pump doses a quantity
that can be programmed in mL. It is possible to set a delay time
before
dosage (Delay) and an interval between subsequent dosages
(Interval) as shown on the diagram:
Trigger
Delay
For example, by setting the interval Interv.= 0 you will get a system
in which the programmed quantity is dosed after each TRIGGER
signal (with the eventual delay set):
Trigger
Delay
You can start the dosage by pressing the + key, which practically
simulates the Trigger signal.
The Trigger signal can be set to N. Open (it is activated when the
input is switched from open to closed mode) or to N. Closed (it is
activated when the input is switched from closed to open mode).
The Trigger signal is locked during the dosage (its reception is
neither stored nor managed).
The Pause input (Remote Control) cannot be programmed and its
activation locks the dosage, while the subsequent deactivation
makes the system wait for the Trigger signal for a new dosage.
The dosage frequency can be modified during operation by
pressing
+
Tempo
•
Pump status
rev.2.0
EN
Operation
Quantity
Interv.
Trigger
Delay
simultaneously.
Trigger mode
Loe or High
Set dosing quantity
•
(display during the
dosing)
11