EN
Model
† Pressure (L
2135Ti
2135Ti-2
2135QTi
2135QTi-2
2135QPTi
2135PTi
† K
= 3dB measurement uncertanity
pA
‡ K
= 3dB measurement uncertanity
wA
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet.
Drain condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily.
Install a properly sized Safety Air Fuse upstream of hose and use an anti-whip device
across any hose coupling without internal shut-off, to prevent hose whipping if a hose fails
or coupling disconnects. See drawing 04581666 and table on page 2. Maintenance
frequency is shown in circular arrow and defined as h=hours, d=days, and m=months.
Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
6. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
Impacting
Sound Level dB (A)
(ISO15744)
)
‡ Power (L
p
96.6
107.6
96.6
107.6
94.2
105.2
94.2
105.2
94.2
105.2
96.6
107.6
7. Coupling
8. Safety Air Fuse
9. Oil
10. Grease - during assembly
11. Grease - through fitting
Free Speed
Sound Level dB (A)
(CAGI/ANSI S12.41)
)
Pressure
w
101.2
101.2
86.0
86.0
86.0
101.2
Vibration
Level
(ISO8662)
Power
m/s²
114.2
5.3
114.2
5.3
96.0
5.3
96.0
5.3
96.0
5.3
114.2
5.3
04584694_ed2