• Maximum enclosure surface temperature (Category 2D): 90 °C (194 °F) (ATEX
relevant)
• Maximum extension surface temperature (Category 1D): 150 °C (302 °F) (ATEX
relevant)
Pressure
• max 10 bar, gauge (145 psi, gauge)
Note: Pressure information for hazardous areas
The device construction allows over-pressure up to 10 bar. This pressure is allowed for
test purposes. The ATEX approval applies to over-pressure between –0.2 and 0.1 bar in
hazardous areas. For higher or lower pressures, the approval is not valid.
Approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• ATEX II 1/2 D
• CSA/FM IS Class I, II, III, Div. 1, Groups A to G, FM Class I, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with 7 to 9 V DC power supply with NAMUR switch
amplifier
• ATEX II 1 G and 1/2 G Eex ia IIC; ATEX II 1 D and 1/2 D, available only with 7 to 9 V DC
power supply with NAMUR switch amplifier