4.1.3.1
Special aspects of plastic head type BM0
WARNING
Electrostatic charge
Danger of explosion in hazardous areas if electrostatic charges develop, for example, in strong airflows in close proximity
to belt conveyors.
Avoid electrostatic charge at the plastic head type BM0 when defining the installation site.
Note
Penetration of water into the plastic head type BM0
Device failure.
To reach IP54 with a plastic head type BM0, make sure that the mounting angle is in the range of -14 to 194° (208°, see
image bellow).
Image 4-1
Mounting angle of plastic head type BM0
4.2
Install
Process connection
DANGER
Protective tube ruptures
Protective tubes that are not suitable for the process or application in question can rupture and result in serious damage to
property and personal injuries
Make sure that the protective tube is suitable for the respective mounting method and application. If necessary, check the
selection and order data of your protective tube.
The devices are delivered with different connection heads and different process connections depending on the
specifications. The following guidelines apply:
● Assemble the process prior to the electrical installation.
● Make sure prior to mounting that the device is appropriate with regard to the process connection, media compatibility,
temperature resistance and measuring range.
● The gaskets used must be suitable for the process connection and resistant to the measured media.
SITRANS TSinsert/TS100/TS200/TS300/TS500 (7MC71.. 7MC72.. 7MC80.. 7MC75.. 7MC65.. 7MC55..)