Instructions for Installation
and Use
Important Safety Information - Please Read Carefully
- Consult a qualified electrician.
- Never look directly at an illuminated UV lamp.
UV-C
- Do not run this unit dry. Do not cover this unit.
DANGER
- Always isolate the unit from mains electricity and turn off the water supply before carrying out any maintenance.
- Always disconnect all pool appliances from the mains supply before servicing.
- Power must be supplied through a Residual Current Device (RCD) with a rated residual operating current not
exceeding 30mA.
- This unit must be earthed. Never use a higher rated fuse than specified below.
- Rating: 220-240V, 50Hz (USA models: 120V, 60Hz). UV110, 128-134 watts. Class 1. IP64.
- The unit must not be submerged in water.
- If the quartz sleeve is cracked, replace it immediately.
- Young children should always be supervised near water.
The unit must be either fully frost protected or
taken inside during the winter months.
Product Information
This unit is manufactured and conforms to:-
Safety: BS EN 60335-1: 2002. BS EN 60335-2-55: 2003
EMC: EN 55015: 2000. EN61000-3-2: 2000 EN61000-3-3: 1995. EN61547:1995.
This unit is CE approved.
POSITIONING THE PRO POOL UNIT
Caution: To prevent this unit falling into water, do not install it above or alongside your pool.
Pro Pool units are weatherproof but not waterproof.The unit can be positioned either on its base on a flat surface,
or mounted on a vertical surface. It must not be submerged in water or placed in a position where water may
collect around the unit. To prevent the unit inadvertently being dropped into the pool, we strongly recommend
that it is securely positioned at least 2 metres from the edge of the pool. Any flexible cabling used between the
unit and the permanent wiring should also be kept to a minimum length. We recommend a maximum length of 1.5
metres. If installing the unit prior to, or without, a filter it is important that a pre-filter is used on the water pump
to prevent dirt being pumped into the unit.The unit can be fitted into the water system as shown below.