Herunterladen Inhalt Inhalt Diese Seite drucken

Main Menu 2; Main Menu; Lines Gamma To Privacy Zone - Monacor TVCCD-800COL Bedienungsanleitung

Hochauflösende farb-überwachungskamera
Vorschau ausblenden Andere Handbücher für TVCCD-800COL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ATW2 The camera automatically adjusts it-
GB
self to the correct colour temperature between
2500 K and 10 000 K.
R:15 B:15 Manual adjustment by setting the
colour parts for red (R) and blue (B):
a) Go to the number for the red part with the
button
b) Adjust the red part with the buttons
and
c) Go to the number for the blue part with the
button
buttons
d) Repeat the adjustments alternately until the
picture reproduction has no more colour
defects.
After the adjustment has been made, select the
next menu line with the button
8) NEXT EXIT CANCEL DEFAULT
From the lower line it is possible to call the main
menu 2 (NEXT), to exit the menu (EXIT), to reset*
all adjustments to the previous adjustments (CAN-
CEL), or to call the factory adjustments*
(DEFAULT). Select the desired menu item with the
button
,
ton Enter.
*This also applies to the adjustments in the main menu 2 and
in all submenus, however, not for the adjustments in the
menu PROTOCOL (fig. 6).
16
so that the number flashes.
.
and adjust the blue part with the
and
.
.
,
, or
and confirm it with the but-
7.2 Main menu 2 (fig. 4)
The following functions can be adjusted here:
Gamma correction
Picture sharpness
Electronic zoom
Mirror-inverted picture display
Compensation of picture spots
Flicker compensation
It is also possible to call the submenus PRIVACY
ZONE and ID MENU.
Select the menu item NEXT in the main menu 1 with
the button
,
,
, or
button Enter (4) to call the main menu 2 (chapter 7.1.3,
operating step 8).

7.2.1 Main menu 2

lines GAMMA to PRIVACY ZONE

1) With the button
which an adjustment is to be changed.
2) GAMMA gamma correction (contrast matching)
Select the value 0,45 or 1 with the button Enter.
0.45 This value is usually used in video sur-
veillance systems.
1 Low contrast for picture processing systems
After the adjustment has been made, select the
next menu line with the button
3) APERTURE sharpness of picture
Select between HIGH (high sharpness), MID (nor-
mal sharpness) and LOW (poor sharpness) with
the button Enter.
After the adjustment has been made, select the
next menu line with the button
4) EZOOM electronic zoom, 2.6-fold as a maximum
Activate the zoom function with the button Enter. A
scale will appear in the menu line EZOOM. Increa-
se or reduce the zoom factor with the buttons
and
.
After the adjustment has been made, select the
next menu line with the button
5) MIRROR mirror function
Switch on or off the mirror function with the button
Enter. Then select the next menu line with the but-
ton
.
6) PRIVACY ZONE After selecting this line, use the
button Enter to call the submenu PRIVACY ZONE
to create a covering mask.
(2, 3) and then press the
or
select the menu line in
.
.
.

Werbung

Inhaltsverzeichnis
loading