3
Make sure the alignment pins are inserted in their provided seats.
4
Join the uprights and the brackets, using the screws supplied.
5
Reassemble the back panels and any other covering elements possibly supplied.
15. Electric connection
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
ensure that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
The systems must be set up in accordance to the norms that regulate manufacture, installa-
tion, use, and maintenance foreseen by the norms in force in the country where the refrige-
ration system is installed.
To ensure normal operation, the maximum variation of the voltage must range between +/-
6% of the nominal value.
Liability
Power
• the supply lines of the electric energy should meet the requirements of power
power supply
• check that the power line:
• has wires with suitable cross section
• be protected against overcurrent and leakage to the ground in compliance
• for the power supply lines measuring more than 4-5 m, increase the section
Automatic
• protect the upstream cabinets with omnipolar circuit breakers with suitable
safety switches
• instruct the operator on the position of the switches to be reached quickly in
05060165 00 15-04-2016
Belgrado 2 - London 3
Customer
provide a power line to the cabinet connection point.
Installer
provide the anchoring devices for all the wires in input and ou-
tput to/from the cabinet.
ARNEG
ARNEG S.p.A. denies all liability with respect to the user or third
parties for:
- damages caused by failures or malfunction of the systems
installed upstream of the cabinet
- damages to the cabinet due to causes arising directly from
malfunction of the electrical system
consumption of the cabinet (chap.10).
with the regulations in force.
of the cables appropriately.
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorized by the same.
characteristics that will also have the function of master switches for cutting
off the line
case of EMERGENCY
DANGER! Live parts. Short circuit Electrocution
The automatic magneto-thermal switches must be such that they do
not open the circuit on the neutral, without simultaneously opening
on the phases and, in any case, must allow complete disconnection
in conditions of category III overvoltage.