Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer
in position on the basin.
3. Slip the slide washer, washer and collar nut
over the threaded base and tighten the collar
nut by hand.
4. Tighten screws.
5. Connect the supply pipes to the angle valves;
cold right - hot left.
6. Connect the pull rod to the pop-up waste.
Large differences in pressure between the hot and cold
water supply should be balanced.

Operation

The mixer is actuated by turning the handles,
left = hot water, right = cold water.
Technical Data
This mixer series-produced with waterdimmer
(flow limiter)
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Test certificate:
Hansgrohe mixers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0,15 MPa.
If the continuous flow heater makes any problems or there
comes not enough water, the flow limiter (3a) located
behind the mousseur must be removed.

English
Spare parts (see page 3)
1
2
3
4
5
6
XXX = Colors
000 chrome plated
090 chrome/gold plated
5 l/min 0,3 MPa
13 l/min 0,3 MPa
max. 1,0 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65° C
WRAS
knob for cold water
knob for hot water
mousseur cpl.
stop unit
pull rod cpl.
fixation cpl.
17291XXX
17292XXX
13085XXX
94149000
94028XXX
13961000

Werbung