Outputs
The Exp 24 has 2 optically isolated digital outputs. These outputs are sourcing only, they provide a
positive voltage when on. Each output can be assigned to any of the internal output functions with
Expert Software. (see software manual). Each output is driven by a smart high side driver rated at 100
mA continuous, short circuit protection at 500 mA as well as over temperature protected. If the load
exceeds 500ma the output turns off to protect itself, the turns back on, if the short persists the output
will continue to cycle on and off rapidly.
The digital outputs are isolated from the main supply voltage and PE.
Function
Output 1 power
Output 1 signal
Output 2 power
Output 2 signal
24 V
Description
Operating voltage range
On state maximum continuous current
On state voltage drop (@ 100 mA)xx
Isolation from PE and Supply
Typical PLC Input Circuit
EXP 24 Manual
PN 47676
Revision H
Terminal
J37
J38
J39
J40
Specification
18 to 32 VDC
250 mA (0.25 Amps)
1.0 V typical
500 V DC
+ 24 V
-
+
Output 1 or 2 Power
Output 1 or 2 Signal
Common
Digital Output Circuit
51
Exp 24 Isolated Output Circuit
1/9/14
Exlar Corporation
952-500-6200