1. Safety instructions
WARNING!
Danger of electrostatic discharge – only use a damp cloth to clean.
WARNING!
If there is danger that the device can be damaged from falling
(pointed, sharp-edged or heavy) objects, the operator must protect
the device.
WARNING!
Exposure to danger which can result from a chemical reaction
between parts of the meter and chemical substances in the vicinity
must be discussed with the manufacturer and the cause must be
eliminated.
WARNING!
The meter must be included in the equipotential bond by
connecting it to the grounded pipeline.
WARNING!
If you wish to add odorants or use solenoid valves, please always fit
them downstream of the meter only. Otherwise, the device may be
damaged.
WARNING!
The gas must not contain suspended particles > 50 µ m. In
addition, the gas must be dry. Otherwise, the meter may be
damaged.
INFORMATION!
The flow through the meter must be free of vibrations and
pulsations in order to avoid measuring errors.
INFORMATION!
Compliance with the specified operating and ambient conditions
as indicated on the type label is absolutely essential for safe
operation of the meter and additional equipment.
730xxxxxe
© Elster GmbH | All rights reserved. Subject to modification
Honeywell
9