Seite 1
69,5 69.5 Pic. 1 Pic. 3 Mod+ Modbus with serial interface RS-485 Mod- max. 1200 m Terminals E1 and E2 Connection for the control signal from the ripple control receiver for tariff switching (PEN) Pic. 2 Pic. 4 Mounting instruction | 431951630C | 2015-08-12...
Deutsch Technische Daten Modbus Bus System Modbus, RTU gemäss IDA Spezifikation Übertragungsraten 4800-9600-19 200-38 400-57 600-115 200. Die Übertragungsrate wird automatisch erkannt Übertragungsmodus Gerade Parität: 8 Databits, 1 Stopbit Ungerade Parität: 8 Databits, 1 Stopbit Keine Parität: 8 Databits, 2 Stopbits Der Übertragungsmodus wird automatisch erkannt Bus Länge (max.) 1200 m (ohne Repeater)
Seite 4
Registers For double registers (4–5, 16–17, 28–29, 30–31, 32–33) the high register is sent first (big_Endian). Partial counters (30–31, 34-35) can be reset by writing 0 in both registers in the same message. Read Description Unit Read Description Unit R Firmware-Version Ex: 11 = FW 1.1 34–35 R/W WT2 partial kWh (multiplier 0,01)
English Assembly and operating instructions Type EEM400-D-MO 65 A Three-phase active power energy meter with Modbus interface, Pic. 1 Description Notes before connecting 1. Do not connect L1, L2 or L3 to N Energy meter with RS-485 Modbus interface enables the 2.
Once the address is selected wait for the root menu to come back ■ Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative:...
Seite 7
Menu to display the value on LCD Start > 3 s T1 total visualization combined heat cooling IT / Data (VISI+) and power station building protocol (VISI+) energy- heating remote alarming management (VISI+) > 20 s tele- temperature sheduler alarming lighting communication (VISI+)
Italiano Istruzioni d’uso e montaggio Modello EEM400-D-MO Contatore d’energia attiva trifase 65 A con interfaccia Modbus, Pic. 1 Descrizione Note per il collegamento Il contatore d’energia con interfaccia RS-485 Modbus 1. Non collegare la fase L1, L2 o L3 a N.
Seite 9
Italiano Dati tecnici Modbus Sistema Bus Modbus, RTU conforme alla specifica IDA Velocità di trasmissione 4800-9600-19 200-38 400-57 600-115 200. (baud rate) La velocità di trasmissione viene riconosciuta automaticamente Modalità di trasmissione Parità pari: 8 bit di dati, 1 bit di stop Parità...
, Tournevis Pozi n° 0, plat Déclaration de conformité CE N° 2, couple de serrage 0,8 Nm Température de –25 à +55 °C (sans condensation Nous, Honeywell Technologies Sàrl, 1180 Rolle, déclarons ■ service selon la norme EN50470) sous notre propre responsabilité que le produit: Environnement Mécanique M2...
Lorsque l’adresse est sélectionnée, attendre que le menu initial s’affiche de nouveau ■ Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Saia-Burgess Controls AG...