Herunterladen Inhalt Inhalt Diese Seite drucken

Putting The Device Into Operation - Emos P5623 Bedienungsanleitung

Wi-fi-funkthermostat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 62
Switching Unit Wiring Diagram
Pump/Motorised Valve Connection Diagram
Pump/
valve
Floor Heating Connection Diagram
Connected
device
Boiler Connection Diagram
Boiler
Pre-installed wire coupler will not be connected.
Expansion Valve/Electric Drive Connection Diagram
Connected
device

PUTTING THE DEVICE INTO OPERATION

Pairing the Control Unit with the Switching Unit
Both thermostat units must be paired before first use.
Pairing enables transfer of information between the control unit and the switching unit.
Setting is done via automated pairing (self-learning).
1. Fit the thermostat gently onto the stand.
Connect the USB power supply with micro USB cable to 230 V mains and plug the cable into the
stand.
2. Correctly connect the switching unit to voltage supply, turn the main switch to the position and
long-press (for at least 10 seconds) the M/A button; a green diode will begin flashing.
3. Press
on the thermostat (transmitter), then press -, which sends you to TECH SET settings.