FRY TOP
Table 1: Operating malfunctions
Problem
Gas odour
Burner does not turn on
Burner does not stay on
GAS CONNECTION
All the gas connection, transformation and pressure control operations must be per-
formed by authorised personnel who must have specific technical skills and special
abilities in the specific sector. This also applies for all extraordinary maintenance op-
erations such as lubrication and/or faucet replacement and thermocouple or burner
EN
replacement.
– Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the
event of need.
– The faucet (not supplied with the appliance) must be installed in a visible and accessible
position in order to easily identify its operating status (open or closed).
GAS SUPPLY TRANSFORMATION
The appliance is marketed with indications of the gas mains used by the manufactur-
er for inspections.
– If the gas mains do not correspond to the one used for inspection, before connecting the
gas mains, the installation technician must "transform" the appliance and indicate the
type of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
– To "transform" and adapt the appliance to the gas mains in use, close the gas supply
faucet and perform the listed operations.
– Burner nozzle replacement.
– Heat power adjustment to minimum
Causes
Temporary leak when flame is
extinguished.
The piezoelectric switch does not
work
The thermocouple is not sufficiently
heated
- 16 -
GAS SUPPLY
Solutions
Close the supply faucet and ventilate
the room
Check piezoelectric switch efficiency
and, if necessary, manually ignite
with a free flame
If the problem persists, contact your
dealer or authorised service centre
Insist with the ignition operation
longer