COMPACT 1.4
• Repair the possible obstruction of the centrifugal blower or the condenser
fan; if the error persists, replace the centrifugal blower or the condenser fan
(remove the outside cover of the unit in order to access the centrifugal blower
or the condenser fan; for the blower, also remove the evaporator cover).
• Replace the 7.5A fuse. To access the condenser fan or centrifugal blower fuses, it
is necessary to take down the interior air distribution panel.
• Replace the electronic control.
!
(If the error persists, contact the Authorised Technical Service).
• Correctly connect the control module terminals (see attached wiring diagram).
• Replace the compressor electronic module(s).
• Replace the compressor(s).
• Check the pressure (the compressors disconnect after 6 bars); if necessary,
recover gas and load 250 g again per circuit.
!
To access the compressors, modules or load connection points, it is
necessary to take down the access cover from the control panel mounted on
the front.
!
(If the error persists, contact the Authorised Technical Service).
• Reprogramme the remote control.
• Replace the remote control's battery and reprogramme.
• Replace electronic control.
• Replace the remote control.
!
(If the error persists, contact the Authorised Technical Service).
Solution
23
EN
®