Herunterladen Inhalt Inhalt Diese Seite drucken

Pre-Installation Checks - RIB MAGIC-Serie Bedienungsanleitung

Nicht selbsthemmender torantrieb für flugeltore
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
G
B
INSTALLATION MAGIC
MAGIC 105°
P
RE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be
flexible during the movement and must move without frictions.
Before the installation of MAGIC, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in
Fig. 1.
Gate features must be uniformed with the standards and laws in
force. The gate can be automated only if it is in a good condition and its
conditions comply with the EN 12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops
are not safe enough.
P
REPARE THE CEMENTATION OF THE BOX
- Dig the pit fully up to the wall or gate post, keeping to the dimensions
indicated in the drawing and remembering that the hinge centre should
fall half way along the Ø 500 dimension (fig. 5).
- Attach a 50 mm PVC tube to the water drain outlet on one side of the
box, and a heavy duty flexible insulating tube of Ø 32 mm max to the
power cable outlet (Electrical connections are made remote from the
unit internally of a sealed junction box, which can be either let into
a wall or surface mounted, but must in any event be installed at a
minimum height above ground sufficient to ensure compliance with
safety standards).
- Position the foundation box in the pit so that the topmost surface of the
cover is flush with the finished floor or paving.
M
AGIC 105° INSTALLATION
- Anchor the box with cement mortar, taking care that none of the mix
finds its way into the enclosure, and checking that the shorter sides
are faultlessly parallel with the gate when in the SHUT position.
- Couple the transmission lever to the output shaft after you have greased
it, checking first that the bronze thrust bearing is fitted to the shaft.
The connection between gate and lever can be made as indicated in
figs 7 and 8.
NB - When converting an existing gate with a load bearing support at
ground level, the MAGIC unit can be utilized as a replacement
support (see installation fig. 8).
- Insert the bolts for cover fixing in places cut into the foundation box.
MAGIC 180°
3
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote controldevice)
automatic
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2020
B: Key selector with manned operation, like code ACG1010
C: Safety edges, like code ACG3010
D: Photocells, like code ACG8026
A
22
22
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of public area*)
(public area)
A
B
C
C
C
C and D
C and D
C and D
B
4
Unrestricted use
C and D
C and D
C and D
5
6

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Magic 105Magic 180

Inhaltsverzeichnis