5
Insert the Calc-Clean tool into the coffee spout.
The Calc-Clean tool is equipped with a magnet. To avoid damage, keep
the Calc-Clean tool away from credit cards, bank cards or other data
carriers that can be damaged by magnetism.
6
Push down the milk container lever.
7
Press the on/off button 3.
The machine is ready for use when the light ring around the on/off
,
button lights up continuously.
8
Place the 1-cup pod holder q with a used coffee pod in the coffee
machine. Close the lid and make sure it is properly locked.
Note: Always put a used coffee pod in the pod holder when you descale the
machine. This pod serves as a 'filter' to prevent the sieve in the pod holder from
getting clogged with scale residues.
9
Put a bowl with a capacity of at least 1.5 litres under the spout to
collect the descaling mixture.
10
Press the CLEAN/CALC CLEAN button to start the descaling cycle.
Never interrupt the descaling cycle. If you did interrupt the descaling
cycle, see problem 'The descaling cycle lasted only 5 minutes' in
chapter 'Troubleshooting'.
It takes a few seconds before the descaling cycle starts.
,
During the descaling cycle, the machine pauses a few times to
,
remove scale deposits from the inside of the SENSEO
During the descaling cycle, the indicators on the control panel on
,
the lid light up clockwise sequentially to indicate that the machine is
descaling.
, The descaling cycle takes about 35 minutes. When the descaling
cycle is finished, the CALC CLEAN indicator lights up again to
indicate that you have to perform 2 rinsing cycles.
rinsing cycles
1
Empty the water reservoir, rinse it and fill it with fresh water.
Caution: Do not refill the water reservoir with hot water or the used
descaling mixture.
EnglisH
25
machine.
®