Other Important Notes; Receiving The Product; Transporting The Product; Installing The Product - Grundfos Conlift1 LS Montage- Und Betriebsanleitung

Kondensathebeanlage
Vorschau ausblenden Andere Handbücher für Conlift1 LS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26

1.2 Other important notes

A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
A red or grey circle with a diagonal bar,
possibly with a black graphical symbol,
indicates that an action must not be taken
or must be stopped.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.

2. Receiving the product

2.1 Transporting the product

WARNING
Harm of body
Death or serious personal injury
- Stack maximum two pallets together
under transportation.

3. Installing the product

Installation must be carried out by
specially trained persons and according to
local regulations.
If not already integrated, a water trap (emission trap)
must be fitted in all inlets.
The Conlift is not designed for outdoor use.

3.1 Mechanical installation

See also the quick guide supplied with the Conlift.
When installing the Conlift, observe the following:
The condensate must run freely into the lifting
station.
The cooling slots in the motor cover must not be
covered.
The lifting station must be easily accessible in
order to facilitate maintenance.
The lifting station must be installed in a
well-illuminated and -ventilated room.
6

3.2 Electrical installation

DANGER
Electric shock
Death or serious personal injury
- The protective earth (PE) of the power
outlet must be connected to the
protective earth of the product. The plug
must have the same PE connection
system as the power outlet.
DANGER
Electric shock
Death or serious personal injury
- The installation must be fitted with a
residual current device (RCD) with a
tripping current less than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- The product must be connected to an
external main switch with a minimum
contact gap of 3 mm (0.12 inch) in all
poles.
Electrical connection must be carried out
by an authorized electrician.
Carry out the electrical connection according to local
regulations.
Check that the supply voltage and frequency
correspond to the values stated on the nameplate.
The power supply cable has a Schuko plug or a free
cable end. The cable has a length of 2 metres.
The electrical connection of a cable with a
free cable end must be carried out by an
authorised electrician.