Light on for 2 seconds at the start of the opening manoeuvre.
Light flashing for the entire duration of the manoeuvre.
Light flashing continuously.
Flashes
1 short flash
1 second pause
Bluebus system error
1 short flash
2 short flashes
1 second pause
Photocell activated
2 short flashes
3 short flashes
Function activation
1 second pause
"Obstacle detection" by force limiter
3 short flashes
4 short flashes
1 second pause
STOP input activation
4 short flashes
5 short flashes
Error on internal parameters
1 second pause
in control unit
5 short flashes
6 short flashes
Maximum limit of consecutive manoeu-
1 second pause
vres or manoeuvres per hour exceeded.
6 short flashes
7 short flashes
1 second pause
Electric circuits fault
7 short flashes
8 short flashes
A command is already present that
1 second pause
disables execution of other commands
8 short flashes
9 short flashes
The automation has been blocked by
1 second pause
a "Block automation" command
9 short flashes
Led
State
Always off
Always on
BLUEBUS
1 flash per second
2 quick flashes
Series of flashes separated
by one second pause
Always off
STOP
Always on
Always off
P.P.
Always on
Always off
OPEN
Always on
Always off
CLOSE
Always on
L1 - L2
Slow flashing
L3 - L4
Slow flashing
8 – English
TABLE 9 - Maintenance light
Signal
TABLE 10 - Flashing light signals (FLASH)
Problem
At the start of the manoeuvre, the devices connected to Bluebus do not correspond to those recognized
during the self-learning phase. One or more devices may be disconnected or faulty; check and, if necessary,
replace them. In case of modifications repeat the device self-learning process (see paragraph 3.4).
One or more photocells do not enable movement or have caused a movement inversion during travel; check
to see if there are any obstructions.
During the movement, the motors encountered excessive resistance; identify the cause and if necessary
increase the level of force of the motors.
At the start of the manoeuvre or during the movement, the STOP input was activated; identify the cause.
Wait at least 30 seconds, then try giving a command and if necessary turn off the power supply. If the
condition persists, there may be a malfunction and the electronic board must be replaced.
Wait a few minutes until the manoeuvre limiting device falls to below the maximum limit.
Wait at least 30 seconds, then try sending a command and if necessary turn off the power supply. If the
condition persists, there may be a malfunction and the electronic board must be replaced.
Check the type of command that is always present; for example, it could be a command from a timer on the
"open" input.
Release the automation by giving the "Automation release" command.
TABLE 11 - Signals given by LEDs on control unit (fig. 7)
Problem
Fault
Serious fault
Everything normal
Input status variation
Various
Activation of the devices connected to the STOP
input
Everything normal
Everything normal
P.P. input activation
Everything normal
OPEN input activation
Everything normal
CLOSE input activation
Change in number of devices connected to
Bluebus or device self-learning not performed
Change in self-learning of the motor types or the
positions of the mechanical stops
Number of manoeuvres
Below 80% of the limit
Between 81% and 100% of the limit
Beyond 100% of the limit
Solution
Check that the control unit is powered. Check that the fuses have not blown: if they
have, check the cause of the fault and replace with others with the same value.
A serious fault has occurred: try disconnecting electrical power from the control
unit. If the problem persists it will be necessary to replace the electronic board.
Control unit works correctly.
Normal if one of the inputs (PP, STOP, OPEN, CLOSE) changes: photocells acti-
vated or a command given via a transmitter.
Refer to Table 10.
Check the devices connected to the STOP input.
STOP input active.
P.P. input not active.
Normal if the device connected to the P.P. input is active.
OPEN input not active.
Normal if the device connected to the OPEN input is active.
CLOSE input not active.
Normal if the device connected to the CLOSE input is active.
The device self-learning process must be performed (see paragraph 3.5).
Self-learning of the mechanical stop positions has not been performed.
Solution